Setback Requirements for the RMF-12 District in Fayetteville

Jurisdiction: FayettevilleCode Version: December 2025

In Fayetteville's RMF-12 (Residential Multi-family - Twelve (12) Units per Acre) district, primary structures must adhere to an urban form that utilizes a front build-to zone of 0 to 25 feet. Side setbacks are established at 5 feet for single-family or two-family dwellings and 8 feet for all other uses, while rear setbacks range from 5 feet for single-family homes to 20 feet for other permitted developments [Section 161.14(E)].

RMF-12 Setback Standards

The Fayetteville Unified Development Code (UDC) establishes specific distance requirements for property boundaries in the RMF-12 district to ensure a consistent urban fabric and appropriate separation between different types of residential uses.

Boundary Type Use or User Type Required Setback/Zone
Front All Permitted Uses Build-to zone between 0 and 25 feet from the front property line
Side Single-family and Two-family dwellings 5 feet
Side All other permitted uses 8 feet
Rear Single-family dwellings 5 feet
Rear All other permitted uses 20 feet

Building Height and Density Regulations

The RMF-12 district is designed to provide medium-density housing in Fayetteville with a maximum density of 12 units per acre [Section 161.14(C)]. The height of structures is also limited based on their proximity to the street.

Regulation Category Requirement
Maximum Density 12 units per acre
Maximum Building Height 2 stories (if within 10 feet of front property line)
Maximum Building Height 3 stories (if more than 10 feet from front property line)
Maximum Building Area 50% of the total lot area
Minimum Buildable Street Frontage 50% of the lot width

Height-Related Setback Increases

If a building in the RMF-12 district exceeds two stories, any portion of the structure above the second story must provide an additional setback from the side boundary line of any adjacent single-family district. This additional setback distance must be equal to the difference between the total height of that specific portion of the building and two stories [Section 161.14(F)].

Urban Form and Street Frontage

To maintain the intended urban character of the RMF-12 district, Fayetteville requires that at least 50% of the lot width be occupied by the vertical side of a building or structure within the designated build-to zone. This is known as the "Minimum Buildable Street Frontage" [Section 161.14(H)]. Additionally, while building area is capped at 50% of the lot, accessory ground-mounted solar energy systems are explicitly excluded from being considered "buildings" when calculating this coverage [Section 161.14(G)].

Sections Cited

  • 161.14 - District RMF-12, Residential Multi-Family — Twelve (12) Units Per Acre
  • 161.14(C) - Density
  • 161.14(E) - Setback Requirements
  • 161.14(F) - Building Height Regulations
  • 161.14(G) - Building Area
  • 161.14(H) - Minimum Buildable Street Frontage