← Back to Dallas AssistantDallas

Setback Requirements for UC-3 Urban Corridor District 3 in Dallas

Jurisdiction: DallasCode Version: March 2025

The UC-3 Urban Corridor District 3 in the City of Dallas requires a minimum 15-foot rear yard setback and has no minimum front yard requirement, though a maximum front yard depth is enforced based on streetscape standards. Side yard setbacks in the City of Dallas UC-3 district vary between zero and 10 feet, depending on the zoning of adjacent properties and the width of neighboring streets [Section 51A-4.127(c)(4)].

Front Yard Setback Requirements in the UC-3 District

The City of Dallas does not impose a minimum front yard setback for the UC-3 Urban Corridor District 3. However, the Dallas Development Code establishes a maximum front yard depth and specific setbacks for taller structures to maintain the urban form.

Front Yard Category Requirement
Minimum Setback No minimum [Section 51A-4.127(c)(4)(A)(i)]
Maximum Setback Smallest distance meeting buffer and pedestrian zone requirements [Section 51A-4.127(c)(4)(A)(ii)]
Urban Form Setback 1 additional foot for every 2 feet in height above 55 feet [Section 51A-4.127(c)(4)(A)(iv)]

Side Yard Setback Requirements in the UC-3 District

In the City of Dallas UC-3 Urban Corridor District 3, side setbacks are determined by the classification of the adjacent land and the proximity to residential neighborhoods.

Adjacency or Condition Minimum Side Yard Requirement
Adjacent to Central Area, Mixed Use, or Urban Corridor Districts 0 feet (5 feet if a setback is provided) [Section 51A-4.127(c)(4)(B)(i)]
Across a street (≤ 64' wide) or alley from a Residential District* 10 feet [Section 51A-4.127(c)(4)(B)(ii)]
Within 330 feet of a Residential District* 10 feet [Section 51A-4.127(c)(4)(B)(ii)]
All other cases 5 feet [Section 51A-4.127(c)(4)(B)(iii)]

*Residential Districts defined here include R, R(A), D, D(A), TH, TH(A), and CH.

Rear Yard Setback Requirements in the UC-3 District

The City of Dallas defines a specific minimum for the rear of properties within this classification to ensure adequate separation between developments.

District Minimum Rear Yard Requirement
UC-3 Urban Corridor District 3 15 feet [Section 51A-4.127(c)(4)(B)(iv)]

Additional Placement Regulations

The City of Dallas requires that any portion of a structure in the UC-3 district exceeding 26 feet in height must remain below a residential proximity slope if it is located near certain protected residential districts [Section 51A-4.127(c)(4)(E)]. Additionally, if a building or parking structure is erected and abuts or is across an alley from a residential or agricultural district, that portion of the building site must be appropriately screened [Section 51A-13.408].

Sections Cited

  • Section 51A-4.127. Urban Corridor Districts.
  • Section 51A-4.127(c)(4). Yard, Lot, and Space Regulations (UC Districts).
  • Section 51A-13.408. Surface Parking Screening and Landscaping.

Have a specific zoning question?

Ask our AI assistant for instant, cited answers from the Dallas code.

Open Chat Assistant