Setback Requirements for the MF-4(A): Multifamily District 4 in Dallas
In the MF-4(A): Multifamily district 4 in the city of Dallas, the minimum required front yard setback is 15 feet. For side and rear yards, the Dallas Development Code requires a minimum setback of 20 feet when the property is adjacent to or across an alley from most lower-density residential districts, and 10 feet in all other cases. Furthermore, buildings exceeding 45 feet in height must provide additional tower spacing setbacks of one foot for every two feet of height above that threshold, up to a maximum of 30 feet [Section 51A-4.116].
Front Yard Setback Requirements
In the Dallas MF-4(A): Multifamily district 4, all structures must maintain a minimum front yard depth of 15 feet [Section 51A-4.116]. Per the general provisions of the Dallas Development Code, the front yard must remain open and unobstructed, with specific exceptions for items such as fences (20 feet or less in height), light poles, and ordinary projections of window sills or cornices [Section 51A-4.401].
Side and Rear Yard Setbacks
The side and rear yard requirements for the MF-4(A): Multifamily district 4 in Dallas are determined by the zoning of the adjacent properties.
General Setback Standards
The Dallas Development Code establishes a tiered approach to side and rear setbacks to ensure adequate separation between high-density multifamily structures and lower-density neighborhoods.
| Condition | Minimum Side Setback | Minimum Rear Setback |
|---|---|---|
| Adjacent to/across an alley from R, R(A), D, D(A), TH, TH(A), CH, MF-1, MF-1(A), MF-1(SAH), MF-2, MF-2(A), or MF-2(SAH) districts | 20 feet | 20 feet |
| All other cases | 10 feet | 10 feet |
[Section 51A-4.116]
Tower Spacing Adjustments
Dallas regulations impose additional setback requirements on high-rise structures within the MF-4(A): Multifamily district 4 to mitigate the impact of building mass. For any portion of a structure that exceeds 45 feet in height, an additional side and rear yard setback is required.
The building must be set back one additional foot for every two feet of height above 45 feet. This cumulative additional setback requirement is capped at a total side or rear yard setback of 30 feet [Section 51A-4.116].
Summary Table of MF-4(A) Setbacks
The following table summarizes the standard yard requirements as established in the Dallas Development Code for the MF-4(A): Multifamily district 4.
| Setback Type | Minimum Requirement |
|---|---|
| Front Yard | 15 feet |
| Side Yard (General) | 10 feet |
| Side Yard (Residential Adjacency) | 20 feet |
| Rear Yard (General) | 10 feet |
| Rear Yard (Residential Adjacency) | 20 feet |
| Tower Spacing (Buildings > 45') | +1' for every 2' of height (Max 30' total) |
[Section 51A-4.116, Section 51A-4.410]
Sections Cited
- Section 51A-4.116: Multifamily Districts
- Section 51A-4.401: Minimum Front Yard
- Section 51A-4.410: Schedule of Yard, Lot, and Space Regulations