MC-2: Multiple Commercial District 2 Setback Requirements in Dallas

Jurisdiction: DallasCode Version: March 2025

In the MC-2: Multiple Commercial District 2 of Dallas, the minimum front yard setback is 15 feet, with an additional 20-foot "urban form" setback required for any portion of a building taller than 45 feet. Side and rear yard setbacks are 0 feet by default, but a minimum 20-foot setback is mandatory when the property is adjacent to or across an alley from specific residential or agricultural districts.

Front Yard Setbacks in the MC-2 District

The City of Dallas mandates a base front yard setback of 15 feet for all structures in the MC-2: Multiple Commercial District 2 [Section 51A-4.126(e)(4)(A)(i)].

However, the Dallas Development Code requires an "Urban Form Setback" to prevent excessive building massing at the street level. Any portion of a building that exceeds 45 feet in height must be set back an additional 20 feet from the front property line [Section 51A-4.126(e)(4)(A)(ii)].

Side and Rear Yard Setbacks

Setback requirements for side and rear yards in the MC-2: Multiple Commercial District 2 are determined by the proximity to residential zoning [Section 51A-4.126(e)(4)(B)].

Residential Adjacency

A minimum side and rear yard setback of 20 feet is required if the MC-2: Multiple Commercial District 2 lot is located adjacent to, or is directly across an alley from, any of the following districts in the City of Dallas:

  • Agricultural [A(A)]
  • Single Family [R, R(A)]
  • Duplex [D, D(A)]
  • Townhouse [TH, TH(A)]
  • Clustered Housing (CH)
  • Multifamily [MF, MF(A)]

Standard Cases

In all other instances where the lot does not abut the residential districts listed above, the City of Dallas does not require a minimum side or rear yard setback (0 feet) [Section 51A-4.126(e)(4)(B)(i)(bb)].

Tower Spacing Requirements

For taller structures in the MC-2: Multiple Commercial District 2, the Dallas Development Code applies a "Tower Spacing" rule. An additional side and rear yard setback of one foot is required for every two feet of building height above 45 feet, up to a maximum total setback of 30 feet [Section 51A-4.126(e)(4)(B)(ii)].

Technical Standards Summary Table

Setback Category Minimum Distance Requirement Applicable Conditions/Notes
Front Yard 15 feet Base requirement for all buildings.
Urban Form Setback +20 feet Required for building portions above 45 feet in height.
Side Yard (Residential) 20 feet When adjacent to or across an alley from R, R(A), D, D(A), TH, TH(A), CH, MF, or MF(A) districts.
Side Yard (Standard) 0 feet All other cases.
Rear Yard (Residential) 20 feet When adjacent to or across an alley from R, R(A), D, D(A), TH, TH(A), CH, MF, or MF(A) districts.
Rear Yard (Standard) 0 feet All other cases.
Tower Spacing 1:2 ratio 1 foot of extra setback per 2 feet of height above 45 feet (max 30 feet total).

Sections Cited

  • Section 51A-4.126. MULTIPLE COMMERCIAL DISTRICTS.
  • Section 51A-4.126(e). MC-2 district.
  • Section 51A-4.126(e)(4). Yard, lot, and space regulations.
  • Section 51A-4.410. SCHEDULE OF YARD, LOT, AND SPACE REGULATIONS.