← Back to Concord AssistantConcord

Maximum Building Height for the RS-6 Residential District in Concord

Jurisdiction: ConcordCode Version: February 10, 2026

In the RS-6 Residential Single-Family District, the maximum permitted building height for single-family structures is 30 feet. This height standard is measured from the ground level to the highest point of the structure, subject to specific exceptions outlined in the Concord Development Code [Section 18.150.070, Section 18.30.030].

Development Standards for the RS-6 District

The RS-6 district, which implements the Low Density Residential land use designation of the Concord general plan, is subject to specific development regulations. These standards ensure that new construction and alterations in the RS-6 district remain compatible with established neighborhood character.

Building Height and Lot Coverage

The following table summarizes the primary development standards for the RS-6 Residential Single-Family District:

Standard RS-6 District Requirement
Maximum Building Height (Single-Family) 30 feet
Maximum Lot Coverage (Single-Family) 35 percent

Measurement and Exceptions

For all residential districts, including the RS-6 district, height is defined as the vertical distance from the highest point of any structure to the ground level directly below [Section 18.150.070].

While the maximum height for the RS-6 district is 30 feet, certain architectural features may exceed this height limit by specific increments, provided they do not exceed 10 percent of the roof area or meet other qualifying criteria:

  • Chimneys: May exceed the height limit by 3 feet.
  • Cupolas, gables, and spires: May exceed the height limit by 10 feet with the approval of a minor exception.
  • Rooftop solar panels: May exceed the height limit by 8 feet.
  • Flagpoles: May exceed the height limit by 10 feet.

All structures in the RS-6 district must also comply with additional general development standards, including setback requirements and provisions for mechanical equipment screening, as detailed in the Concord Development Code [Section 18.150.070, Section 18.150.080].

Sections Cited

  • Section 18.30.030 (Table 18.30.030 – RR and RS districts – Development standards)
  • Section 18.150.070 (Height limits and exceptions)
  • Section 18.150.080 (Mechanical equipment screening)

Have a specific zoning question?

Ask our AI assistant for instant, cited answers from the Concord code.

Open Chat Assistant
Maximum Building Height for the RS-6 Residential District in Concord | Concord Zoning Guide