← Back to Charlotte AssistantCharlotte

RC: Research Campus Zoning District Regulations in Charlotte

Jurisdiction: CharlotteCode Version: June 01, 2023 (Amended March 23, 2026)

The RC Research Campus Zoning District in the City of Charlotte is primarily intended to accommodate large-scale research campuses within mixed-use environments, emphasizing a development form of taller structures and high walkability [Section 7.1.E]. Key standards for this district include a minimum district size of five acres and a base maximum building height of 120 feet, which can be increased to 250 feet through the use of voluntary development bonuses [Table 7-1, Table 7-3]. Residential developments in the City of Charlotte RC Research Campus Zoning District focus on high-density options like multi-family stacked dwellings and dormitories, while lower-density single-family, duplex, and triplex homes are prohibited [Table 15-1].

Purpose and Intent of the Research Campus District

The City of Charlotte established the RC Research Campus Zoning District to support research-intensive uses that require a dense, pedestrian-oriented urban setting. These campuses are designed to house a mix of supportive uses to serve employees, residents, and visitors, including retail, personal services, and eating and drinking establishments [Section 7.1.E].

Allowed Uses

Uses in the RC Research Campus Zoning District are categorized as Permitted by-right (X), Permitted with Prescribed Conditions (PC), or requiring Conditional Zoning (C or C/PC).

Residential and Mixed-Use

The RC Research Campus Zoning District prioritizes high-intensity residential living.

  • Permitted by-right (X): Dormitories, Live/Work Dwellings, Multi-Family Stacked Units, Quadraplexes (singular buildings), and Residential Care Facilities.
  • Permitted with Prescribed Conditions (PC): Continuum Care Retirement Communities (CCRC), Multi-Family Attached Units, Group Homes, Multi-Dwelling Developments, and Single Room Occupancy (SRO) [Table 15-1].

Commercial and Office

The City of Charlotte allows a broad range of office and supporting commercial uses within the RC Research Campus Zoning District.

  • Permitted by-right (X): Art Galleries, Arts or Fitness Studios, Broadcasting Facilities (no antennae), Commercial Fitness Centers, Convention Centers, Financial Institutions, Hotels/Motels, Industrial Design firms, Medical/Dental Offices, General Offices, Outdoor Markets, Personal Service Establishments, Research and Development (R&D) facilities, Retail Goods Establishments, Retail Goods Showrooms, and Specialty Food Service.
  • Permitted with Prescribed Conditions (PC): Amusement Facilities (Indoor), Broadcasting Facilities (with antennae), Commercial Kitchens, Micro-Production of Alcohol, Reception Facilities, Research and Development with a light industrial component, and Restaurants/Bars [Table 15-1].

Institutional and Industrial

  • Permitted by-right (X): Community Centers, Cultural Facilities, Educational Facilities (all levels), Government Office/Facilities, Healthcare Institutions, Places of Worship, Public Safety Facilities, and Social Service Facilities.
  • Permitted with Prescribed Conditions (PC): Adult Care Centers, Childcare Centers (Standard and Large), Public Works Facilities, Beneficial Fill Sites, Industrial Craft, Industrial Light, and Light Assembly.
  • Conditional Zoning Required (C/PC): Movie Studios [Table 15-1].

Transportation and Infrastructure

  • Permitted by-right (X): Parking Structures (as a principal use) and Public Transit Facilities.
  • Permitted with Prescribed Conditions (PC): Utility Transmission/Distribution, Wireless Telecommunications, and various Temporary Uses (e.g., Mobile Food Vendors) [Table 15-1].

Prohibited Uses

The City of Charlotte prohibits several use types within the RC Research Campus Zoning District to maintain its character as a dense, high-activity campus.

  • Residential: Single-family detached dwellings, duplexes, triplexes, and manufactured homes.
  • Commercial: Adult uses, outdoor amusement facilities, animal shelters, car washes, heavy retail, greenhouses/nurseries, nightclubs, raceways, and vehicle dealerships.
  • Industrial: Agriculture-industrial processes, airports, crematoriums, general industry, LCID landfills (principal use), outdoor storage yards, and quarries.
  • Transportation: Standalone surface parking lots, truck stops, and vehicle operations facilities [Table 15-1].

Technical Development Standards

The following tables outline the specific dimensional, siting, and parking requirements for the RC Research Campus Zoning District in the municipality of Charlotte.

Lot and Building Standards

Category Requirement
Minimum District Size 5 acres [Table 7-1]
Minimum Lot Width 25 feet [Table 7-1]
Maximum Building Coverage 60% [Table 7-1]
Maximum Building Height (Base) 120 feet [Table 7-3]
Maximum Building Height (with Bonus) 250 feet [Table 7-3]

Siting and Setbacks

Frontage Type Setback Line (from future back of curb)
Main Street 24 feet [Table 7-2]
4-5 Lane Avenue/Boulevard 20 feet [Table 7-2]
6 or More Lane Avenue/Boulevard 24 feet [Table 7-2]
Secondary 16 feet [Table 7-2]
Side Setback (not abutting Neighborhood 1) 0 feet [Table 7-2]
Rear Setback (not abutting Neighborhood 1) 0 feet [Table 7-2]

Vehicle Parking Requirements

The RC Research Campus Zoning District follows Tier 2 parking standards, which mandate both minimums and maximums [Section 19.2.A].

Use Category Minimum Parking Maximum Parking
Residential (General) 1 per dwelling unit 2 per dwelling unit
Dormitory 1 per 4 dorm rooms 1 per dorm room
Nonresidential (unless listed below) 1 per 1,000 sq. ft. GFA 1 per 250 sq. ft. GFA
Hotel/Motel 0.5 per guest room 1.5 per guest room
Medical/Dental Office 1 per 1,000 sq. ft. GFA 1 per 250 sq. ft. GFA

Sections Cited

  • Section 7.1.E
  • Section 7.2
  • Table 7-1
  • Table 7-2
  • Table 7-3
  • Section 15.1
  • Section 15.2
  • Table 15-1
  • Section 19.2
  • Table 19-1

Have a specific zoning question?